Golden Technologies Outdoor Fireplace 18 24 30 User Manual

INSTALLATION AND OPERATING  
INSTRUCTIONS  
FOR VENT-FREE  
OR VENTED INSTALLATIONS  
®
GOLDEN BLOUNT “TEXAS FLAME II” GAS LOGS  
NATURAL GAS OR L.P.  
18“ - 24“ & 30“ SIZE SETS  
Warning: If the information in this manual is  
not followed exactly, a fire or explosion may  
result causing property damage, personal  
injury or loss of life  
• Do not store or use gasoline or other  
flammable vapors or liquids in the  
vicinity of this or any other appliance.  
• What to do if you smell gas:  
- Do not try to light any appliance.  
- Do not touch any electrical switch;  
do not use any phone in your  
building.  
- Immediately call your gas supplier  
from a neighbor’s phone.  
- If you cannot reach your gas  
supplier, call a fire department.  
- Installation and service must be  
performed by a qualified installer,  
service agency or the gas supplier.  
The Golden Blount vent-free gas  
log sets comply with the National  
Safety Standards and are tested  
and design certified by CSA to  
ANSI Z21.11.2-2000, unvented  
heaters Z21.60a-2000 decorative  
gas appliances for installation only  
in a woodburning, masonry or UL  
listed manufactured fireplace or in a  
Golden Blount or any other CSA  
approved vent-free fireplace. This  
product may be burned with the  
fireplace damper in either a closed  
or open position.  
Warning: Logs must be arranged so that the  
flames only touch bottom back log or front  
ember log. Flames must not touch any other  
log in set or any part of firebox.  
MANUFACTURED BY:  
INC.  
This is an unvented gas-fired heater. It  
uses air (oxygen) from the room in which  
it is installed. Provisions for adequate  
combustion and ventilation air must be  
provided.  
4301 WESTGROVE DRIVE  
ADDISON, TX. 75001  
 
CAUTION  
NOTE! CARBON MONOXIDE POISONING MAY LEAD TO DEATH.  
Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea. If you have  
these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people -  
pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol, those at high  
altitude - are more affected by carbon monoxide than others.  
WARNING: ANY CHANGES TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS AND CAN VOID  
WARRANTY.  
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid  
burns or clothing ignition.Young children should be carefully supervised when they are in the same room as the  
appliance.  
Note: Installation and repair should be done by a qualified person well trained in the installation of such  
appliances.You may need a building permit from your local Building Commissioner before installing this  
appliance.  
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater. Do  
not burn with glass doors in a closed position.  
GOLDEN BLOUNT VENT-FREE LOG SET COMPONENT PARTS  
24" & 30" SETS 7-LOGS  
18" SETS 5-LOGS  
BURNER ASSEMBLY  
ELBOW CLAMP  
GLOWING EMBERS  
CONNECTOR TUBE  
BLACK ROCK  
SET SIZE  
FIREPLACE WIDTH  
DEPTH  
OPENING HEIGHT  
FRONT  
BACK  
18"  
24"  
30"  
24"  
30"  
36"  
18"  
21 1/2"  
30"  
14"  
16"  
16"  
20"  
21"  
21"  
If a hood is not installed, there must be only noncombustible material from the top of the fireplace  
opening to a height of 20". A combustible mantel or shelf must be at least 39" up from the opening. If a  
hood is installed on the fireplace, the clearance can be reduced to 7".  
3
 
BURNER SYSTEM INSTALLATION  
Before starting installation, find out if local and state codes approve vent-free gas logs. If unvented gas logs are not  
approved, the installation must be made with the fireplace damper partially open and locked to assure the minimum  
vent area required by local codes or the National Gas Fuel Code (ANSI Z223.1-latest edition). Use the damper clamp  
provided.  
Clean the firebox thoroughly. In the future, frequent cleaning may be required due to excessive lint from carpeting  
and other materials. All burner components must always be kept clean.  
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot,  
creosote, ashes and loose paint by qualified chimney cleaner.  
If a 1/2“ gas supply line is not already installed in the fireplace, a call to your plumber is recommended.  
Check to make sure the gas supply is the same type (natural or L.P.) as listed on the rating plate attached to the  
burner. Note the approved gas pressure chart.  
Model  
GB-TFII-18 GB-TFII-18 GB-TFII-24/30 GB-TFII-24/30  
Gas Type  
Natural  
L.P.  
Natural  
L.P.  
Max Input  
30,000btu/hr  
19,000btu/hr  
30,000btu/hr 38,000btu/hr  
26,000btu/hr 22,700but/hr  
35,000btu/hr  
28,500btu/hr  
Min Input  
Gas Inlet Pressure  
Maximum  
10.5 IN. wc  
5.0 IN. WC  
3.5 IN. WC  
14.0 IN. WC  
11.0 IN. WC  
10.0 IN. WC  
10.5 IN. WC  
5.0 IN. WC  
3.5 IN. WC  
14.0 IN. WC  
11.0 IN. WC  
10.0 IN. WC  
Minimum  
Regulator Pressure  
Manifold pressure check should be made with the appliance burning in the high setting.  
A 1/8“ NPT test plug is located on the regulator.  
LP Installations require an external regulator in addition to the regulator installed in the burner system.  
The LP tank could explode if the additional regulator is not installed.  
When checking gas inlet pressure, the appliance must be isolated from the gas supply line by closing its individual  
manual shut off valve during and pressure testing of the gas supply at test pressures equal to or less then 1/2 psig.  
(3.5 KPA)  
Centrally locate the burner/grate unit inside the firebox. Position burner/grate unit towards rear of the firebox.  
Connect the burner to the gas supply using the connector tube and brass elbow supplied in the kit. Some installa-  
tions may require different fittings that are available from hardware stores.  
Turn on the gas with the burner valve in the “OFF” position and check all fittings for leaks using soapy water. Do not  
use a flame to leak test.  
4